Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS. / Gammelgaard, Bente; Larsen, E.H.

I: Talanta, Bind 47, Nr. 2, 1998, s. 503-507.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Gammelgaard, B & Larsen, EH 1998, 'Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS', Talanta, bind 47, nr. 2, s. 503-507.

APA

Gammelgaard, B., & Larsen, E. H. (1998). Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS. Talanta, 47(2), 503-507.

Vancouver

Gammelgaard B, Larsen EH. Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS. Talanta. 1998;47(2):503-507.

Author

Gammelgaard, Bente ; Larsen, E.H. / Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS. I: Talanta. 1998 ; Bind 47, Nr. 2. s. 503-507.

Bibtex

@article{508ee1a1ca3b47b8b78fbb5c8ffc5b9a,
title = "Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS",
abstract = "Aqueous solutions and blood plasma spiked with selenite (Se(IV)), selenate (Se(VI)), selenomethionine (SeMet) or trimethylselenonium (TMSe) iodide were analyzed by Zeeman-corrected electrothermal atomic absorption spectrometry (ETAAS) using palladium as a chemical modifier, and by inductively coupled plasma mass spectrometry (ICP-MS). Using ETAAS, the sensitivities for Se(IV), SeMet and TMSe in aqueous solution were similar, whereas the sensitivity of Se(VI) was 63% of that value. In blood plasma, the ETAAS sensitivities of Se(IV) and Se(VI) were equal, whereas the sensitivities of SeMet and TMSe were 87 and 56%, respectively, of that value. In contrast, the ICP-MS sensitivities obtained for Se(VI), TMSe and SeMet were between 96 and 98% of that obtained for Se(IV) in aqueous solution and in blood plasma. It is concluded, that ICP-MS is superior to ETAAS as the problem of differences in sensitivity of the selenium species when using ETAAS are not prevalent when using the ICP-MS technique. (C) 1998 Elsevier Science B.V. All rights reserved",
author = "Bente Gammelgaard and E.H. Larsen",
year = "1998",
language = "English",
volume = "47",
pages = "503--507",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "2",

}

RIS

TY - JOUR

T1 - Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS

AU - Gammelgaard, Bente

AU - Larsen, E.H.

PY - 1998

Y1 - 1998

N2 - Aqueous solutions and blood plasma spiked with selenite (Se(IV)), selenate (Se(VI)), selenomethionine (SeMet) or trimethylselenonium (TMSe) iodide were analyzed by Zeeman-corrected electrothermal atomic absorption spectrometry (ETAAS) using palladium as a chemical modifier, and by inductively coupled plasma mass spectrometry (ICP-MS). Using ETAAS, the sensitivities for Se(IV), SeMet and TMSe in aqueous solution were similar, whereas the sensitivity of Se(VI) was 63% of that value. In blood plasma, the ETAAS sensitivities of Se(IV) and Se(VI) were equal, whereas the sensitivities of SeMet and TMSe were 87 and 56%, respectively, of that value. In contrast, the ICP-MS sensitivities obtained for Se(VI), TMSe and SeMet were between 96 and 98% of that obtained for Se(IV) in aqueous solution and in blood plasma. It is concluded, that ICP-MS is superior to ETAAS as the problem of differences in sensitivity of the selenium species when using ETAAS are not prevalent when using the ICP-MS technique. (C) 1998 Elsevier Science B.V. All rights reserved

AB - Aqueous solutions and blood plasma spiked with selenite (Se(IV)), selenate (Se(VI)), selenomethionine (SeMet) or trimethylselenonium (TMSe) iodide were analyzed by Zeeman-corrected electrothermal atomic absorption spectrometry (ETAAS) using palladium as a chemical modifier, and by inductively coupled plasma mass spectrometry (ICP-MS). Using ETAAS, the sensitivities for Se(IV), SeMet and TMSe in aqueous solution were similar, whereas the sensitivity of Se(VI) was 63% of that value. In blood plasma, the ETAAS sensitivities of Se(IV) and Se(VI) were equal, whereas the sensitivities of SeMet and TMSe were 87 and 56%, respectively, of that value. In contrast, the ICP-MS sensitivities obtained for Se(VI), TMSe and SeMet were between 96 and 98% of that obtained for Se(IV) in aqueous solution and in blood plasma. It is concluded, that ICP-MS is superior to ETAAS as the problem of differences in sensitivity of the selenium species when using ETAAS are not prevalent when using the ICP-MS technique. (C) 1998 Elsevier Science B.V. All rights reserved

M3 - Journal article

VL - 47

SP - 503

EP - 507

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 2

ER -

ID: 44288441