Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives. / Bendahl, Lars; Hansen, Steen Honoré; Gammelgaard, Bente; Sturup, Stefan; Nielsen, Camilla.

I: Journal of Pharmaceutical and Biomedical Analysis, Bind 40, Nr. 3, 2006, s. 648-52.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Bendahl, L, Hansen, SH, Gammelgaard, B, Sturup, S & Nielsen, C 2006, 'Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives', Journal of Pharmaceutical and Biomedical Analysis, bind 40, nr. 3, s. 648-52. https://doi.org/10.1016/j.jpba.2005.09.021

APA

Bendahl, L., Hansen, S. H., Gammelgaard, B., Sturup, S., & Nielsen, C. (2006). Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives. Journal of Pharmaceutical and Biomedical Analysis, 40(3), 648-52. https://doi.org/10.1016/j.jpba.2005.09.021

Vancouver

Bendahl L, Hansen SH, Gammelgaard B, Sturup S, Nielsen C. Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives. Journal of Pharmaceutical and Biomedical Analysis. 2006;40(3):648-52. https://doi.org/10.1016/j.jpba.2005.09.021

Author

Bendahl, Lars ; Hansen, Steen Honoré ; Gammelgaard, Bente ; Sturup, Stefan ; Nielsen, Camilla. / Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives. I: Journal of Pharmaceutical and Biomedical Analysis. 2006 ; Bind 40, Nr. 3. s. 648-52.

Bibtex

@article{00beedc52609488989343529d644dbdb,
title = "Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives",
abstract = "Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.",
keywords = "Bromine Compounds, Bromine Radioisotopes, Chromatography, High Pressure Liquid, Indicators and Reagents, Mass Spectrometry, Preservatives, Pharmaceutical, Reproducibility of Results, Spectrophotometry, Ultraviolet",
author = "Lars Bendahl and Hansen, {Steen Honor{\'e}} and Bente Gammelgaard and Stefan Sturup and Camilla Nielsen",
year = "2006",
doi = "10.1016/j.jpba.2005.09.021",
language = "English",
volume = "40",
pages = "648--52",
journal = "Journal of Pharmaceutical and Biomedical Analysis",
issn = "0731-7085",
publisher = "Elsevier",
number = "3",

}

RIS

TY - JOUR

T1 - Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives

AU - Bendahl, Lars

AU - Hansen, Steen Honoré

AU - Gammelgaard, Bente

AU - Sturup, Stefan

AU - Nielsen, Camilla

PY - 2006

Y1 - 2006

N2 - Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.

AB - Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.

KW - Bromine Compounds

KW - Bromine Radioisotopes

KW - Chromatography, High Pressure Liquid

KW - Indicators and Reagents

KW - Mass Spectrometry

KW - Preservatives, Pharmaceutical

KW - Reproducibility of Results

KW - Spectrophotometry, Ultraviolet

U2 - 10.1016/j.jpba.2005.09.021

DO - 10.1016/j.jpba.2005.09.021

M3 - Journal article

C2 - 16417984

VL - 40

SP - 648

EP - 652

JO - Journal of Pharmaceutical and Biomedical Analysis

JF - Journal of Pharmaceutical and Biomedical Analysis

SN - 0731-7085

IS - 3

ER -

ID: 44053950