HPLC-ICP-MS compared with radiochemical detection for metabolite profiling of H-3-bromohexine in rat urine and faeces
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Standard
HPLC-ICP-MS compared with radiochemical detection for metabolite profiling of H-3-bromohexine in rat urine and faeces. / Jensen, B.P.; Gammelgaard, B.; Hansen, S.H.; Andersen, J.V.
I: Journal of Analytical Atomic Spectrometry, Bind 20, Nr. 3, 2005, s. 204-209.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - HPLC-ICP-MS compared with radiochemical detection for metabolite profiling of H-3-bromohexine in rat urine and faeces
AU - Jensen, B.P.
AU - Gammelgaard, B.
AU - Hansen, S.H.
AU - Andersen, J.V.
PY - 2005
Y1 - 2005
N2 - H-3-Bromohexine was dosed to rats as a model compound to allow comparison of HPLC-ICP-MS detection on bromine to radiochemical detection in an in vivo drug metabolism study. Metabolite profiles were obtained in urine and faeces extracts. No influence of the methanol gradient on the bromine response was observed in the range of 18 - 75% methanol. The sensitivity obtained by HPLC- ICP-MS was almost two orders of magnitude better than on-line H-3 radiochemical detection. For ICP- MS, the limit of detection was calculated to be 69 nM Br ( injection volume 100 mu l), corresponding to an absolute limit of detection of 1.3 ng of bromohexine on-column. This allowed ICP- MS detection of several minor metabolites that were not detected using radiochemical detection. Furthermore, metabolites that had lost the radioactive label were detected due to the bromine in the metabolites. As ICP- MS is also more selective than UV and molecular MS detection, it could thus be applied as an alternative detector in drug metabolism studies
AB - H-3-Bromohexine was dosed to rats as a model compound to allow comparison of HPLC-ICP-MS detection on bromine to radiochemical detection in an in vivo drug metabolism study. Metabolite profiles were obtained in urine and faeces extracts. No influence of the methanol gradient on the bromine response was observed in the range of 18 - 75% methanol. The sensitivity obtained by HPLC- ICP-MS was almost two orders of magnitude better than on-line H-3 radiochemical detection. For ICP- MS, the limit of detection was calculated to be 69 nM Br ( injection volume 100 mu l), corresponding to an absolute limit of detection of 1.3 ng of bromohexine on-column. This allowed ICP- MS detection of several minor metabolites that were not detected using radiochemical detection. Furthermore, metabolites that had lost the radioactive label were detected due to the bromine in the metabolites. As ICP- MS is also more selective than UV and molecular MS detection, it could thus be applied as an alternative detector in drug metabolism studies
M3 - Journal article
VL - 20
SP - 204
EP - 209
JO - Journal of Analytical Atomic Spectrometry
JF - Journal of Analytical Atomic Spectrometry
SN - 0267-9477
IS - 3
ER -
ID: 44287858